4.11.3 COMGetConfig
Retrieves the serial port settings; e.g. port number, baud rate, parity check.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
COMConfig A cluster containing CommPort, BaudRate, Parity,
DataBits, StopBits, TxMode and PortAddress data
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in