4.5.2 DIOGetConfig
Reads digital input and output configuration data stored in the Registry or a configuration file. The
application calls this function by passing the configuration data’s memory address
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program..
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
DIOGetConfig A cluster containing PortArray and NumOfPorts
data.
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in