4.4.5 AOCurrentOut
Accepts a floating-point current value, scales it to the proper binary number, and writes that
number to an analog output channel to change the output current.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
Channel The channel number of a specified device
Va l ue The current value needing to be changed to be
a binary value.
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in