
4.4.5 AOCurrentOut
Accepts a floating-point current value, scales it to the proper binary number, and writes that
number to an analog output channel to change the output current.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
Channel The channel number of a specified device
Va l ue The current value needing to be changed to be
a binary value.
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in
Kommentare zu diesen Handbüchern