Startup of Motion Control CardStartup of Motion Control Card
Utility OperationUtility Operation Set parameters by clciking “Parameter Setting”Group 1 is for Pulse Output setting
Utility OperationUtility Operation Set parameters by clicking “Parameter Setting”Group 2 is for HW Input Signal setting
Utility OperationUtility Operation Set parameters by clicking “Parameter Setting”Group 3 is for IN and OUT pin setting
Utility OperationUtility Operation Set parameters by clicking “Parameter Setting”Group 4 is for Encoder, SW Limit and Compare setting
Utility OperationUtility Operation Set parameters by clicking “Parameter Setting”Home Parameter is for Home setting
Utility OperationUtility Operation All the settings will be saved to registry
Utility OperationUtility Operation Check IO by clicking “Input Status” buttonAll input signals can be checkedIN0/Z is for encoder indexIN3/H is for O
Utility OperationUtility Operation Check IO by clicking “Input Status” buttonOUT4~7 can be controlled OUT6 is for ServoONThe latest ending status of
Utility OperationUtility Operation Check IO by clicking “Input Status” buttonReal counter (encoder feedback) & logical counter (command counter)
Utility OperationUtility Operation Motion control can be done by clicking “Operation”P-to-P, continuous drive, line interpolation and arc interpolati
AgendaAgenda Installation & Testing of PCI-1240U Installation & Testing of PCI-1202U
Utility OperationUtility Operation Potion can be plotted by clicking “Profile Monitor”Any 2 axis can be selected to be traced
Installation & Testing of PCI-1202UInstallation & Testing of PCI-1202U
Driver installationDriver installation Driver: AMONetDriver.exeSource: Companion CD\Drivers\PCI\1240.exeWebsite: http://support.advantech.com.tw/supp
Locations of Jumpers and DIP SWsLocations of Jumpers and DIP SWsIsolated DI/DOBoard IDAMONet Extension
Utility OperationUtility Operation Start Manu Æ Programs ÆAMONet Device Manager ÆAMONet Device Manager
Utility OperationUtility Operation Click button first
Utility OperationUtility Operation Select PCI-1202U, then you’ll see the Baudrate setting and on-board DIO control
Utility OperationUtility Operation Click “+” button to see slave modules that are connected to PCI-1202Up to 64 modules per ring
Utility OperationUtility Operation Test of DIO slave modulesAbout BoardID setting, please refer AMAX series manualDODI
Utility OperationUtility Operationreset position value Test of motion 1-axis slave modules
Installation & Testing of PCI-1240UInstallation & Testing of PCI-1240U
Utility OperationUtility Operation Home mode settingPlease refer the software manual ORG->Slow down->Go back (backward)->Accelerate to MaxVe
Utility OperationUtility Operation Motion IO setting
Utility OperationUtility Operation Pulse output and input (encoder) setting
Utility OperationUtility Operation Velocity profile can be checked
The End & Thank you.The End & Thank you.
Driver installationDriver installation Driver: PCI1240.exeSource: Companion CD\Drivers\PCI\1240.exeWebsite: http://support.advantech.com.tw/support/D
Jumper and DIP SW SettingJumper and DIP SW Setting Make sure you have installed the software driver first before you plug in the PCI-1240U. Adjust t
Locations of Jumpers and DIP SwitchesLocations of Jumpers and DIP SwitchesCompare Out SelectionBoard IDOpto-isolationEmg Level SelectionPulse Output T
Signal ConnectionSignal Connection Signals are classified as shown belowFunction Signals NoteDriving P+P, P+N, P-P, P-NFeedback ECAP, ECAN, ECBP, ECB
Utility OperationUtility Operation Start Manu Æ Programs ÆAdvantech Automation ÆMotion Æ PCI-1240 Æ PCI-1240 Utility
Utility OperationUtility Operation Select BoardID first by “Board Selection” button