4.3.6 AIBinaryIn
Reads an analog input channel and returns the unscaled result.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
Channel Channel value specifies a digital or analog channel
number
TrigMode 0-normal (software), 1-external
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type
Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
Va lu e Return the value of the specified channel
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in