Advantech PCL-848A/B Bedienungsanleitung Seite 37

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 84
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 36
CHAPTER 3 PROGRAMMING REFERENCE
31
3.4.14. PPOLLU
Purpose:
This command executes a Parallel Poll Unconfigure. It directs a device to not
respond to a parallel poll. It can e be addressed to the interface bus or to a specific
device.
Offset:
PPOLLU%=30
Syntax:
CALL PPOLLU%(ADDR%) ----BASIC
CALL ABSOLUTE(ADDR%,PPOLLU%) ----BASIC Compiler
Parameter:
ADDR’ - The address of the device to be unconfigured. If s 0 <= addr <= 30, the
specified device is uncon figured. Otherwise, all the devices are unconfig-
ured.
Bus Activity:
- If 0 <= addr <= 30
ATN is set true.
UNL is sent.
LAD is sent.
MTA is sent.
PPC is sent.
PPD is sent.
- If addr < 0 or addr > 30
ATN is set true.
PPU is sent.
Seitenansicht 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 83 84

Kommentare zu diesen Handbüchern

Keine Kommentare