51 Appendix C
C.16 Read Digital Input Data — BASE+1CH
D15 ~ D0 Digital input data
D0 LSB of the input data
D15 MSB of the input data
C.17 Write Calibration Command — BASE+1EH
D7 ~ D0 Calibration result data
D0 the least significant bit (LSB) of the data
D7 the most significant bit (MSB)
Table C.16: Register for Read Digital Input Data
Base
Addr.
1514131211109876543210
1CH R Read digital input data
D1
5
D1
4
D1
3
D1
2
D11 D1
0
D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
Table C.17: Register for write calibration command
Base
Addr.
1514131211109876543210
1EH W Write calibration command
X X X X X X X X D7 D6 D5 D4 D3 D2 D1 D0
Note: If you want to calibrate the range of the specific
channel, be sure to write the value to BASE+14H
first. Next, write the data to this register for calibra-
tion purposes. Lastly, write the value to BASE+18H
to strobe the parameters into EEPROM.
Kommentare zu diesen Handbüchern