Advantech I/O Module 5000 Series Bedienungsanleitung Seite 25

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 24
www.advantech.com/products
Online Download
13-25
8
5
44
10
Serial Communication
Cards
9
Device Servers &
Gateways
8
Industrial Ethernet
7
Industrial Monitors
6
Automation Panel PCs
Operator Panels
Building Automation
Systems
3
Energy Automation
2
Hazardous Location
1
Motion Control
11
Embedded Auto.
Computers
12
PACs
13
M2M I/O
14
Distributed Nano
Controllers
15
RS-485 I/O
16
Automation Software
Ethernet I/O
17
DAQ Boards
18
ADAM-5000 Controller
Selection Guide
System
ADAM-5510M
ADAM-5510KW
ADAM-5510E
ADAM-5510/TCP
ADAM-5510KW/TCP
ADAM-5510E/TCP
ADAM-5510EKW/TP
ADAM-5560CE
ADAM-5560KW
CPU
80188
Intel Atom Z510P
1.1 GHz
RAM
640 KB 1 GB DDR2 SDRAM
Flash ROM
256 KB -
Flash Memory
256 KB -
Flash Disk
1 MB -
OS
ROM-DOS WinCE
Control Software
ADAM-5510M:
Borland C
ADAM-5510KW:
KW SoftLogic
Borland C
ADAM-5510/TCP:
Borland C
ADAM-5510KW/TCP:
KW SoftLogic
ADAM-5510E/TCP:
Borland C
ADAM-5510EKW/TP:
KW SoftLogic
ADAM-5560CE:
C/C++ and .NET
ADAM-5560KW:
KW SoftLogic
Real-time Clock
Yes
Watchdog Timer
Yes
COM1
RS-232 RS-232/485 RS-232 RS-232/RS-485 RS-232/485
COM2
RS-485
COM3 (Programming)
RS-232 (TX, RX, GND) RS-232/485
COM4
RS-232/485
I/O Slots
4 8 4 8 7
Power Consumption
4 W 17 W
Isolation
Communication
2,500 V
DC
(COM2 RS-485)
2,500 V
DC
(COM2 RS-485)
1,500 V
DC
(COM1,
COM3, COM4 RS-485)
Communication
Power
3,000 V
DC
I/O Module
3,000 V
DC
Diagnosis
Status Display
Power, CPU, Communication, Battery Power, User Define
Self Test
Yes, while ON
Software
Diagnosis
Yes
Communication
Network
RS-232/485 Ethernet (RJ-45) Ethernet (2 x RJ-45)
Speeds
1,200 bps ~ 115.2 kbps 10/100 Mbps 10/100 Mbps
Max. Distance
4,000 feet (1.2 km) 150 m 150 m
Data Format
N, 8, 1, 1 - - -
Max. Nodes
32 32
256 for Ethernet, 32
for RS-485
256 for Ethernet, 32
for RS-485
256 for Ethernet,
32 for RS-485
Protocol
User Defined,
Modbus/RTU
User Defined,
Modbus/RTU
User Defined,
Modbus/RTU,
Modbus/TCP
User Defined,
Modbus/RTU,
Modbus/TCP
Modbus/RTU,
Modbus/TCP
Remote I/O
Modbus Device
Power
Requirements
10 ~ +30 V
DC
Environment
Operating
Temperature
-10 ~ 70°C (14 ~ 158°F) 0 ~ 55°C (32 ~ 131°F)
Storage
Temperature
-25 ~ 85°C (-13 ~ 185°F)
Humidity
5 ~ 95%
Page
online online online online 13-32
Seitenansicht 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 31 32

Kommentare zu diesen Handbüchern