Seitenansicht 8
3 EKI-1321/1322 User Manual
Chapter 1 Overview
1.2 Features
Expand up 255 serial ports for one Windows 2000/XP/Vista (x86) host
Link any serial device to a cellular network
Supports high transmission speed up to 921.6 kbps
Supports LED indicators: easy to diagnose
Supports various operation modes: VCOM, RVCOM, TCP Server/Client, UDP
Server/Client, RFC2217 and SMS Tunnel
Supports multi-access: allows a max. of 5 hosts to access one serial port
A max of 4 hosts can be accessed in TCP client and command response mode
Mounts on DIN-rail, or panel
15 KV ESD protection for all signals
2KV isolation protection for all serial signals (EKI-1321 only)
1.3 Specifications
Cellular Interface
Standard Compliance: GSM/GPRS Quad Band 850/900 and 1800/1900MHz
Antenna Connector: Reverse SMA
GPRS Standard:
GPRS Multi-slot: Class 10
GPRS Terminal Device: Class B
GPRS Coding Schemes: CS1 to CS4
LAN Interface
Ethernet: 10/100 Mbps auto sensing
No. of Ports: 1
Port Connector: RJ45
Protection: Built-in 1.5 KV magnetic isolation
Serial Interface
Interface: RS-232/422/485, software selectable
No. of Ports:
EKI-1321:1 w/ isolation
EKI-1322: 2
Port Connector: DB9 male
Baud Rate: 50 bps to 921.6 kbps, any baud rate setting
Parity: None, Even, Odd, Space, Mark
Data bits: 5, 6, 7, 8
Stop bits: 1, 1.5, 2
Flow control: RTS/CTS, DTR/DSR, XON/XOFF, None
Signals:
RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485: Data+, Data-, GND
Protection: 15 KV ESD for all signals