Compliance Certification Services Inc.
Report No.: 40614203-D Date of Issue: July 15, 2004
Page 9 Rev. 00
6 INSTRUMENT AND CALIBRATION
6.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated once a year or in accordance with the manufacturer's recommendations, and is
traceable to recognized national standards.
6.2 TEST AND MEASUREMENT EQUIPMENT
The following list contains measurement equipment used for testing. The equipment conforms
to the requirement of CISPR 16-1, ANSI C63.2 and other equivalent standards.
Calibration of all test and measurement, including any accessories that may effect such
calibration, is checked frequently to ensure the accuracy. Adjustments are made and
correction factors are applied in accordance with the instructions contained in the respective
manual.
Equipment Used for Emission Measurement
Conducted Emission Test Site # 3
Name of Equipment Manufacturer Model Serial Number Calibration Due
EMI Test Receiver R&S ESHS30 828144/003 08/07/2004
LISN R&S ESH2-Z5 843285/010 01/08/2005
LISN EMCO 3825/2 9003-1628 07/27/2004
Note: The measurement uncertainty is less than +/- 2.83dB, which is evaluated as per the NAMAS NIS 81 and
CISPR/A/291/CDV.