2.3 Mounting
2.3.1 Rack mounting
EKI-4524I comes with a rack-mounted kit and can be mounted in an EIA standard size, 19-inch rack. The
Switch can be placed in a wiring closet with other equipment.
Perform the following steps to rack-mount the switch:
1. Position one bracket to align with the holes on one side of the switch and secure it with the smaller
bracket screws. Then attach the remaining bracket to the other side of the Switch.
Figure 2.2: Attach mounting brackets with screws
2. After attaching the mounting brackets, position the EKI-4524I in the rack by lining up the holes in the
brackets with the appropriate holes on the rack. Secure the Switch to the rack by a screwdriver with
the rack-mounting screws.
Figure 2.3: Mount the switch in the 19” rack
Note: For proper ventilation, allow about at least 4 inches (10 cm) of clearance on the front and 3.4
inches (8 cm) on the back of the Switch. This is especially important for enclosed rack installation.