Chapter 4 Register Structure and Format 29
4.9 Clear Interrupt and FIFO BASE+8
and BASE+9
Writing data to either of these two bytes clears the interrupt or the
FIFO.
Table 4-8: Registers to clear interrupt and FIFO
4.10 Programmable Timer/Counter
Registers BASE+24, BASE+26,
BASE+28 and BASE+30
The four registers of BASE+24, BASE+26, BASE+28 and BASE+30
are used for the 82C54 programmable timer/counter. Please refer to
Appendix A data sheets for detailed application information.
Note!: Users have to use a 16-bit (word) command to read/write
each register.
Write Clear Interrupt and FIFO
Bit # 7 6 5 4 3 2 1 0
BASE+9 Clear FIFO
BASE+8 Clear Interrupt