Chapter 4 Register Structure and Format 27
4.7 Control Register BASE+6
The write-only register BASE+6 allows users to set an A/D trigger
source and an interrupt source.
Table 4-6: Control register
SW Software trigger enable bit
Set 1 to enable software trigger, and set 0 to disable.
PACER PACER trigger enable bit
Set 1 to enable pacer trigger, and set 0 to disable.
EXT External trigger enable bit
Set 1 to enable external trigger, and set 0 to disable.
Note!: Users cannot enable SW, PACER and EXT concurrently.
GATE External trigger gate function enable bit
Set 1 to enable external trigger gate function, and set 0 to disable.
IRQEN Interrupt enable bit
Set 1 to enable interrupt, and set 0 to disable.
ONE/FH Interrupt source bit
Set 0 to interrupt when an A/D conversion occurs, and set 1 to
interrupt when the FIFO is half full.
Write Control Register
Bit # 7 6 5 4 3 2 1 0
BASE + 6 ONE/FH IRQEN GATE EXT PACER SW