Compliance Certification Services Inc.
Report No.: 60707201-F Refer No.: 60321204 Date of Issue: July 7, 2006
Page 9 Rev. 00
Conducted Emission Test Site # A
EQUIPMENT MFR MODEL
SERIAL
NUMBER
CAL.
DUE
TEST RECEIVER
R&S ESHS20 840455/006 02/06/2007
LISN (EUT) SCHWARZBECK NSLK 8127 8127382 01/02/2007
LISN SOLAR 8012-50-R-24-BNC 8305114 01/02/2007
BNC CABLE JYE BAO RG-223/U BNC A 2 10/ 08/2006
THERMO-
HYGRO METER
TOP HA-202 9303-1 02/22/2007
Note: The measurement uncertainty is less than +/- 2.83dB, which is evaluated as per the NAMAS NIS 81 and
CISPR/A/291/CDV.
7. LINE CONDUCTED & RADIATED EMISSION TEST
7.1 LIMIT
Maximum permissible level of Line Conducted Emission
Class A (dBuV) Class B (dBuV)
FREQUENCY
(MHz)
Quasi-peak Average Quasi-peak Average
0.15 - 0.5 79 66 66 - 56 56 - 46
0.50 - 5.0 73 60 56 46
5.0 - 30.0 73 60 60 50
Note: The lower limit shall apply at the transition frequency.
Maximum permissible level of Radiated Emission measured at 10 meter
Class A (dBuV/m) Class B (dBuV/m)
FREQUENCY
(MHz)
Quasi-peak Quasi-peak
30 – 230 40 30
230 - 1000 47 37
Note: The lower limit shall apply at the transition frequency.
Maximum permissible level of Radiated Emission measured at 3 meter
Class A (dBuV/m) Class B (dBuV/m)
FREQUENCY
(MHz)
Average Peak Average Peak
Above 1000 59.3 79.3 53.9 73.9
Note: The lower limit shall apply at the transition frequency.