Compliance Certification Services Inc.
Report No.: 60707201-F Refer No.: 60321204 Date of Issue: July 7, 2006
Page 14 Rev. 00
7.4 TEST RESULTS
Line Conducted Emission
Model: IPC-5120 Test Mode: Mode 1
Temperature: 21°C Humidity: 65% RH
Test Results: Passed Tested by: Jason Lee
(The chart below shows the highest readings taken from the final data.)
Six Highest Conducted Emission Readings
Frequency Range Investigated 150 kHz to 30 MHz
Freq
(MHz)
Read
Level
(dBuV)
Factor
(dB)
Level
(dBuV)
Limit
Line
(dBuV)
Over
Limit
(dB)
Reading
Type
(P/Q/A)
Line
(L1/L2)
0.153 43.30 0.13 43.43 79.00 -35.57 P L1
0.735 34.11 0.15 34.26 73.00 -38.74 P L1
2.809 37.32 0.25 37.57 73.00 -35.43 P L1
0.153 43.38 0.13 43.51 79.00 -35.49 P L2
0.735 34.05 0.15 34.20 73.00 -38.80 P L2
2.809 36.08 0.25 36.33 73.00 -36.67 P L2
NOTE: The emission level was or more than 2dB below the Average limit, so no re-check anymore.