Dialogic
®
System Release 6.1 CompactPCI for Windows
®
Release Update 121
Resolved IPY00037004 -- 127 IP Host IP channels sporadically fail to receive Global Call
events resulting from gc_AnswerCall( ),
gc_DropCall( ), or gc_Extension( ) calls.
Resolved IPY00033102 -- 120 IP Host Supervised transfer fails. Party B gets
GCEV_XFER_FAIL with “reason 5800”.
Resolved IPY00044273 -- 174 IP Media Session
Control
A request to re-INVITE from audio to T.38 fax using
gc_ReqModifyCall( ) in
IP_T38_MANUAL_MODIFY_MODE fails with
GCEV_MODIFY_CALL_FAIL event.
Resolved IPY00081853 -- 194 IP Media Session
Control RTP
The Dialogic
®
IPT Board sporadically sends RTP
with the destination MAC address set to all zeros
(for example, 00.00.00.00.00.00).
Resolved IPY00092115 -- 196 IPT Boards Resetting IPT device media addresses causes a
loss of speech path.
Resolved IPY00081301 -- 193 IPT Boards An internal IPT device hardware malfunction
prevented completion of the SIP or H.323 call
control message on the channel. As a result,all
subsequent outbound call attempts failed with an
''Invalid State'' error message. See the Dialogic
®
Global Call IP Technology Guide document update
regarding the new error message related to this
issue.
Resolved IPY00079365 -- 186 IPT Boards A Dialogic
®
IPT Board channel locked when it failed
to connect to the remote media address. The
problem occurred when the application made an
outbound IP call from the IPT cPCI host, and the
remote carrier responded with an 18x (SDP)
containing their remote media IP information. If that
remote media IP address is unreachable, the IPT
Board does not post either the GCEV_EXTENSION
events with the media connection details, nor does
it post a subsequent (and required)
GCEV_CONNECTED. The channel becomes
unusable, and a reboot is required.
Resolved IPY00078978 -- 185 IPT Boards A Dialogic
®
IPT Board channel locked when it failed
to connect to a remote media address. The channel
became unusable and required a board
reinitialization.
Resolved IPY00045304 -- 176 IPT Boards On Dialogic
®
IPT Boards, ipm_StartMedia( ) or
ipm_ModifyMedia( ) caused 5 to 20 msec of invalid
data injected toward the CT Bus. This was observed
with DefaultTimeslotEncoding and CT Bus settings
in either companding setting (A- or U-law), with
G.711 IP sessions. This invalid data caused audible
clicks on the TDM side of the session.
Issues Sorted By Type, Dialogic
®
System Release 6.1 CompactPCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description