EKI-6538 User Manual 32
Figure 3.12: ARL Aging Time Setting
DI/DO Setting
By simply setting up a web-based configuration, you can manage the con-
nection between two digital inputs and two digital outputs that are built
into EKI-6538. These are invaluable when integrating field indicators or
alarm devices that will respond to messages according to individual
users configured setting.
The DI/O default setting of EKI-6538 is ----
DI0=DO0=HIGH; DI1=DO1=HIGH.
The number with blue boldface character means the current DI/O status
(1=HIGH, 0=LOW), you can press the Refresh button to update it.
DO can be decided by the logic result of both DI, or assigned HIGH/
LOW directly. Choose the option in the pull down list of "Assign DO"
and "Logic" columns for your prefer setting.
Output from DI : DO equals to the logic result of the checked DI
Invert from DI: DO equals to the opposite logic result of the checked DI
Warning: If you choose "Output from DI" or "Invert from
DI", please remember to check the DI behind.