All product specifications are subject to change without notice Last updated : January 2005
DIN-rail Mounting
Streamline your system with industry standard
DIN-rails
Panel/Wall Mounting
Use this special bracket to mount modules on
any flat surface
Piggybacking
Save space by stacking the modules, one on top
of the other
Plug-in Terminal Block
Save time by leaving wiring intact while
connecting or disconnecting modules
Analog and Digital I/O Total Solution
RTD Input Modules
An RTD module is popular for temperature measurement.
Unlike traditional designs, the ADAM-4015 provides six
RTD input channels for different types of RTD signals
as a cost-effective solution for industrial and building
automation. Occasionally, broken external wiring can lead
to inaccurate current values. The ADAM-4015 provides
a broken wiring detection function so users can easily
troubleshoot this.
Analog Output Modules
The ADAM-4021 analog output module supplies
single-channel analog output in a range of
voltages and currents. In order to fully fit
multi-channel analog output modules, the ADAM-4024
provides 4 universal type output channels. Moreover, it is
designed with 4 digital inputs for integrating applications,
such as emergency latch outputs or users default triggers.
It uses optical isolators to prevent ground loop effects and
limit damage from power surges. You can specify slew
rates and start-up currents.
Analog Readback (ADAM-4021 Only)
The analog output module's ADC (Analog to Digital
Converter) is independent of the DAC, so it provides true
readback of the analog output signal to the microprocessor.
While the ADC is not intended to provide highly accurate
measurement of the output data, it indicates that analog
output is being produced as intended. It also lets you easily
detect output fault conditions due to improper wiring or
unexpected loads.
Digital Input and
Output Modules
The ADAM-4050 features seven digital input channels
and eight digital output channels. The outputs are
open-collector transistor switches that you can control
from the host computer. You can also use the switches
to control solid-state relays, which in turn can control
heaters, pumps or other power equipment. The host
computer can use the module's digital inputs to determine
the state of limit switches, safety switches or remote
digital signals.
The ADAM-4051 is a 16-ch. digital input module, built
with 3000 V
DC
optical isolation, suitable for critical
applications. Different from other modules, the ADAM-
4051 accepts 10 ~ 50 V input voltage to fit various digital
signals, such as 12 V
DC
, 24 V
DC
, 48 V
DC
. Moreover, users
can read the current status from the LED indicators on
the front panel.
The ADAM-4052 provides eight digital input channels:
six fully independent isolated channels and two isolated
channels with a common ground. All have 5000 V
RMS
isolation to prevent ground loop effects and prevent
damage from power surges on the input lines.
The ADAM-4053 provides 16 digital input channels for dry
or wet contact signals signals. For dry contact, the effective
distance from DI to contact point is up to 500 m.
The ADAM-4055 offers 8-ch. isolated digital inputs and
8-ch. isolated digital outputs for critical applications. The
inputs accept 10 ~ 50 V voltage, and the outputs supply
5 ~ 40 V
DC
open collector. Considered to be very user-
friendly, the ADAM-4055 is also built with LED indicator
for easy status reading.
Counter/Frequency
Module
The ADAM-4080/4080D isolated counter/frequency
modules have two 32-bit counter channels and a built-in
programmable timer for frequency measurement.
Programmable Alarm Output
The ADAM-4080/4080D modules include digital alarm
functions. You can set alarm values (32-bit) into the module
from your host computer.
Programmable Digital Filter and Thresh-
old
The ADAM-4080/4080D modules include a unique
programmable digital filter to reject noise on the input
signal. You can specify separate time constants to provide
stable output readings.
Programmable Preset Value
The ADAM-4080 module includes a programmable
preset mode. You can preset the value of a counter into
the module from your host computer.
Front Panel Display
The ADAM-4080D module's 5-digit LED displays the
data being sent over an RS-485 line to the host computer.
The module can be programmed to show either channel
0 or channel 1.
Relay Output Modules
As with other ADAM modules, the ADAM-4060/4068 relay
modules are controlled remotely and store configuration
data in EEPROM. The ADAM-4060/4068 provide 4/8
channels, half being Form A and the rest being Form
C. These modules are excellent for on/off control or
low-power switching applications.