Advantech EDG-4508R+ Bedienungsanleitung Seite 53

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 108
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 52
47 Chapter 3
Command Listen Port
Each port has its own command listen port to accept connected request of
other network device. So, the command listen port can’t be set the same
value. You can use ‘AT command’ to change the port setting via the com-
mand listen port.
Data Idle Timeout
The default is 60 seconds. If you want to keep connection continually,
you can key-in “0”.
The following commands are available for EDG-4516(R)+ and EDG-
4508(R)+.
Command Function
ATDT<IP
address>
<TCP port>
<CR>
“Forms a TCP connection to the specified host.
Ex: ATDT 192.0.55.22:5201
In above example, the EDG-4516(R)+ and EDG-
4508(R)+ forms a raw TCP connection to the net-
working device (192.0.55.22). The TCP port is 5201.”
ATA <CR> Answering an incoming call
+++<CR> Returns the user to the command prompt when
entered from the serial port during a remote host
connection.
Seitenansicht 52