Advantech PPC-140 Bedienungsanleitung Seite 160

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 194
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 159
142
PPC-120/140 User's Manual
Programming the Watchdog Timer
To program the watchdog timer, you must write a program which writes
I/O port address 443 (hex). The output data is a time interval value. The
value range is from 01 (hex) to 3F (hex), and the related time interval is
from 1 sec. to 63 sec.
Data Time Interval
01 1 sec.
02 2 sec.
03 3 sec.
04 4 sec.
••
••
••
3F 63 sec.
After data entry, your program must refresh the watchdog timer by
rewriting the I/O port 443 (hex) while simultaneously setting it. When you
want to disable the watchdog timer, your program should read I/O port
443 (hex).
Seitenansicht 159
1 2 ... 155 156 157 158 159 160 161 162 163 164 165 ... 193 194

Kommentare zu diesen Handbüchern

Keine Kommentare