User ManualEKI-152X series1/2/4-port RS-232/422/485 Serial Device Servers
EKI-1521/1522/1524 User Manual 4Software Utility: Advantech Serial Device Server Configuration Utility Driver support: Windows 2000/XP/Vista/7, Wind
Chapter 22 Getting Started
EKI-1521/1522/1524 User Manual 62.1 Understanding EKI-152X seriesThe EKI-152X series are network-based, serial device servers for connecting RS-232/42
7 EKI-1521/1522/1524 User ManualChapter 2 Getting Started2.1.2 COM Port Redirector (Virtual COM Port)Advantech Serial Device Server Configuration Util
EKI-1521/1522/1524 User Manual 82.1.2.2 Multi-Access Mode (Shared COM port mode)Most of serial devices are connected directly and physically to the PC
9 EKI-1521/1522/1524 User ManualChapter 2 Getting Started2.1.3 TCP Server ModeIn TCP server mode, you might initiate the TCP connection from host to E
EKI-1521/1522/1524 User Manual 102.1.5 Serial Tunneling ModeTwo native serial devices can communicate over an Ethernet network without anyintermediate
11 EKI-1521/1522/1524 User ManualChapter 2 Getting Started2.2 HardwareIn this section, we will give you an overview of EKI-152X series hardware and in
EKI-1521/1522/1524 User Manual 122.2.2 Dimensions (Units: mm)2.2.2.1 EKI-1521 and EKI-1522Figure 2.7 Front View of EKI-1521/1522Figure 2.8 Side View o
13 EKI-1521/1522/1524 User ManualChapter 2 Getting StartedFigure 2.9 Back View of EKI-1521/1522Figure 2.10 Top View of EKI-1521/1522
EKI-1521/1522/1524 User Manual iiCopyrightThe documentation and the software included with this product are copyrighted 2010by Advantech Co., Ltd. All
EKI-1521/1522/1524 User Manual 142.2.2.2 EKI-1524Figure 2.11 Front View of EKI-1524Figure 2.12 Side View of EKI-1524
15 EKI-1521/1522/1524 User ManualChapter 2 Getting StartedFigure 2.13 Back View of EKI-1524Figure 2.14 Top View of EKI-15242.3 Connecting HardwareNext
EKI-1521/1522/1524 User Manual 162.3.1.1 Panel/Wall MountingThe EKI-152X series can be attached to a wall using the included metal brackets.Each brack
17 EKI-1521/1522/1524 User ManualChapter 2 Getting StartedFigure 2.17 DIN-rail Step 22.3.2 Network ConnectionEKI-152X series has 2x RJ-45 that support
EKI-1521/1522/1524 User Manual 182.3.4 Serial ConnectionEKI-152X series provides one, two, or four ports DB9 (male) connectors. RS-232/422/485 pin ass
19 EKI-1521/1522/1524 User ManualChapter 2 Getting Started3. Upon executing the setup program, the Welcome Dialog Box will be pop-up. Press the "
EKI-1521/1522/1524 User Manual 205. The Setup program will specify a default installation path: C:\Program Files\Advantech eAutomation\Serial Device S
Chapter 33 Configuration
EKI-1521/1522/1524 User Manual 223.1 Configuration Utility OverviewEKI-152X series serial device servers provide an easy-to-use utility to configure
23 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.2 Discovering Serial Device Servers3.2.1 Auto SearchingAdvantech Serial Device Server Config
iii EKI-1521/1522/1524 User Manual Declaration of ConformityCEThis product has passed the CE test for environmental specifications when shieldedcable
EKI-1521/1522/1524 User Manual 24Select the device in this sub-tree. The first tab on the “Configuration Area” shows thesummary of “Basic Information”
25 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.2.2 Clear Device List and Search AgainYou can click the button on the Quick Tool Bar. The
EKI-1521/1522/1524 User Manual 263.2.3 Manual AppendingUsing “Add IP address to Favorite” or “Search a Range of IP addresses” function,you are able to
27 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.3 Network SettingsThis section explains how to configure the EKI-152X series network using t
EKI-1521/1522/1524 User Manual 28IP address, Subnet Mask, Default Gateway:You can choose from four possible IP Configuration modes --- Static, DHCP,B
29 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.4 Serial SettingsThis section explains how to configure the EKI-152X series serial communica
EKI-1521/1522/1524 User Manual 30 Baud Rate: The EKI-152X series serial device server supports baud rate from 50 to 921.6Kbps.While setting the baud
31 EKI-1521/1522/1524 User ManualChapter 3 Configuration Flow Control: The EKI-152X series serial device server provides four options: None, XOn/XOff
EKI-1521/1522/1524 User Manual 32Ignore PurgeSome application program will purge the serial port while it is the first time opens thisserial port. You
33 EKI-1521/1522/1524 User ManualChapter 3 Configurationremote serial devices and equipments over LAN or WAN. The EKI-152X seriescomes with a COM port
EKI-1521/1522/1524 User Manual iv6. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage.7. T
EKI-1521/1522/1524 User Manual 34nections, so multiple hosts can transmit/receive data to/from the same serial portsimultaneously. Every host can tran
35 EKI-1521/1522/1524 User ManualChapter 3 ConfigurationProtocolThe EKI-152X series provides TCP/IP and UDP two protocols. In settings, you canchoose
EKI-1521/1522/1524 User Manual 36time, the EKI-152X series will disconnect temporarily. When the data comes to theEKI-152X series, it will reconnect a
37 EKI-1521/1522/1524 User ManualChapter 3 ConfigurationSet the number of network device which you want to connect. You can set maximumsixteen network
EKI-1521/1522/1524 User Manual 38networking device. If you want serial device running application program to connect/disconnect to different devices d
39 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.6 Accessible IP SettingsAccessible IP setting allows you to add or remove the blocking host
EKI-1521/1522/1524 User Manual 403.7 Auto Warning Settings3.7.1 Email AlertConsult your ISP or Network Administrator for the proper SMTP mail server s
41 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.7.3 System EventCold StartThis refers to starting the system from power off. When performing
EKI-1521/1522/1524 User Manual 42Ethernet 2 DownThe Ethernet 2 port has link failure condition. When the Ethernet 2 links fail, the EKI-152X series wi
43 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.9 Administrator SettingsThe configuration utility provides several administrator settings fo
v EKI-1521/1522/1524 User Manual ContentsChapter 1 Overview...11.1 Introduction ...
EKI-1521/1522/1524 User Manual 443.9.1 Import/Export Device SettingThe utility allows importing or exporting the serial device server’s setting via th
45 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.9.3 Locate the Serial Device ServerIf there are many serial device severs need your manageme
EKI-1521/1522/1524 User Manual 46Click “Unlock Device” to unlock the serial device sever, and you need to fill in thepassword you have set up before.
47 EKI-1521/1522/1524 User ManualChapter 3 Configuration3.9.5 Restore to Factory Default SettingsThe configuration utility provides this function to l
EKI-1521/1522/1524 User Manual 483.9.6 Update FirmwareAdvantech continually upgrades its firmware to keep up with the ever-expendingworld of computing
49 EKI-1521/1522/1524 User ManualChapter 3 ConfigurationWait for few seconds to process the updating firmware. After downloading the firm-ware complet
EKI-1521/1522/1524 User Manual 50
Chapter 44 Setting COM Redirector
EKI-1521/1522/1524 User Manual 524.1 Setting COM Redirector (Virtual COM port)Advantech COM port mapping software is a serial COM port redirector that
53 EKI-1521/1522/1524 User ManualChapter 4 Setting COM RedirectorThe COM ports in the “Virtual Com Ports” listing are now available for use by Win-dow
EKI-1521/1522/1524 User Manual vi3.3 Network Settings... 273.4 Seria
EKI-1521/1522/1524 User Manual 544.1.2 Manual MappingRight click the serial device name on the sub-tree of Device Server List area andselect the “Manu
55 EKI-1521/1522/1524 User ManualChapter 4 Setting COM RedirectorAuto Reconnect PropertySometimes, the connection between Advantech serial device serv
EKI-1521/1522/1524 User Manual 564.1.3 Manual Direct Mapping Virtual COM PortClick the button on the Quick Took area, you can add a target by select
57 EKI-1521/1522/1524 User ManualChapter 4 Setting COM Redirector4.2 Running Diagnostic TestThe purpose of this test is to make sure the communication
EKI-1521/1522/1524 User Manual 582. Select which COM port you want to run a diagnostic test, and then press “Test” button to process the testing.Signa
Chapter 55 Web-Based Configuration
EKI-1521/1522/1524 User Manual 605.1 OverviewEKI-152X series serial device server can be configured through a web interface. Byusing a standard web br
61 EKI-1521/1522/1524 User ManualChapter 5 Web-Based ConfigurationBy Windows Internet Explorer
EKI-1521/1522/1524 User Manual 625.3 SystemYou can change the Device Name and Device Description on this page. You can alsoenable or disable the Web,
63 EKI-1521/1522/1524 User ManualChapter 5 Web-Based Configuration5.5 Port ConfigurationThere are Basic, Operation Mode, and Advanced Setting in the s
Chapter 11 Overview
EKI-1521/1522/1524 User Manual 645.6 MonitorYou can monitor the serial ports settings, statistic, and the connected IP address byclick on Monitor func
65 EKI-1521/1522/1524 User ManualChapter 5 Web-Based Configuration5.7 Auto Warning (Alarm)You can set the e-mail server and SNMP Trap server in the Se
EKI-1521/1522/1524 User Manual 665.8 Change PasswordYou can change the serial device server password on here:Note! All new configurations will take ef
67 EKI-1521/1522/1524 User ManualChapter 5 Web-Based ConfigurationIf you have set a password via the configuration utility or Telnet or serial console
EKI-1521/1522/1524 User Manual 685.9 Import/Export Device SettingsYou can Import or Export the serial device server all setting as the “.conf” file fo
69 EKI-1521/1522/1524 User ManualChapter 5 Web-Based Configuration5.10 RebootThe configuration will take effect after clicking “Save” button. But all
EKI-1521/1522/1524 User Manual 70
Chapter 66 Telnet Configuration
EKI-1521/1522/1524 User Manual 726.1 OverviewThe purpose of the Console Configuration is to help you manage your device in con-sole mode. One of the m
73 EKI-1521/1522/1524 User ManualChapter 6 Telnet ConfigurationConnecting SuccessAfter connection the serial device server in Telnet console mode, you
EKI-1521/1522/1524 User Manual 21.1 IntroductionAdvantech's EKI-1521, EKI-1522, and EKI-1524 series of Industrial Device Servers(the following ma
EKI-1521/1522/1524 User Manual 74HelpYou might type the “help” command or press <Tab> twice to show the supportedcommand list.[Usage] help[Funct
75 EKI-1521/1522/1524 User ManualChapter 6 Telnet ConfigurationSystem[Usage] system[Function] Show firmware version, device name and description[Usage
EKI-1521/1522/1524 User Manual 76[Usage] port nn or port all[Function] Show the “nn”th port or all ports information[Usage] port nn desc XXXX[Function
77 EKI-1521/1522/1524 User ManualChapter 6 Telnet Configuration[Usage] port nn||all type 232|422|485 flow 0|1|2|3[Function] Set serial ports’ type and
EKI-1521/1522/1524 User Manual 78[Usage] mvcom[Function] Show all serial ports mode and related information[Usage] mvcom nn|all[Function] Set the “nn”
79 EKI-1521/1522/1524 User ManualChapter 6 Telnet ConfigurationmdataShow and setup the Data mode[Usage] mdata[Function] Show all serial ports mode and
EKI-1521/1522/1524 User Manual 80netShow and setup the Ethernet port configuration[Usage] net 1|2[Function] Show the first or second Ethernet port sta
81 EKI-1521/1522/1524 User ManualChapter 6 Telnet Configurationpassword[Usage] password new XXXX[Function] Set new password [XXXX: maximum 31 characte
EKI-1521/1522/1524 User Manual 82monitorShow the serial ports settings, statistic, and connected IP address[Usage] monitor port 1|2|…|16 setting[Funct
83 EKI-1521/1522/1524 User ManualChapter 6 Telnet ConfigurationalarmShow or configure the auto warning functionFor more detailed setting for auto warn
3 EKI-1521/1522/1524 User ManualChapter 1 Overview1.2 Features Expand up 4096 serial ports for one Windows 2000/XP/Vista/7 host Provides dual 10/100
EKI-1521/1522/1524 User Manual 84[Usage] time[Function] Show the current time information[Usage] time YYYYMMDDhhmmss[Function] Modify the current time
Appendix AA Pin Assignments
EKI-1521/1522/1524 User Manual 86A.1 Pin AssignmentsA.1.1 RS-232 Pin AssignmentsA.1.2 RS-422/485 Pin AssignmentsA.1.2.1 1. RS-422A.1.2.2 2. RS-485Pin
87 EKI-1521/1522/1524 User ManualAppendix A Pin Assignments
www.advantech.comPlease verify specifications before quoting. This guide is intended for referencepurposes only.All product specifications are subject
Kommentare zu diesen Handbüchern